A guide for sunbed servicing.
We frequently get asked about the guide lines for sunbed servicing. When our sunbeds are installed in your premises they are prepared for use with a strict scrutiny in mind. In order to keep your sunbeds in good working order we recommend that you perform a general service on your sunbeds every year. We also suggest that an in-depth check needs to be performed every 5-10 years depending on the age and the frequency of the use of the equipment.
Engineer
Below is a guide on what checks need to be performed in a specific time scale. These checks can only be performed by a qualified sunbed engineer.
Guide
| Part | Basic service guide | Comprehensive service guide |
| The plug + socket | Every year | Every 5 years |
| Electrical Wires | Every year | Every 5 years |
| Grid Wiring + connectors | Every year | Every 5 years |
| Audio System(if applicable) | Every year | Every 5 years |
| Noise Filter | Every year | Every 10 years |
| Compressors | Every year | Every 10 years |
| Solenoids | Every year | Every 10 years |
| Condensate pump(if applicable) | Every year | Every 10 years |
| Aqua Spray system(if applicable) | When necessary | When necessary |
| Aroma System(if applicable) | When necessary | When necessary |
| Air conditioning system (if applicable) | Every year | Every 10 years |
| Electronic/ Magnetic Ballasts | Every year | Every 5 years |
| Ventilation panel | Every year | Every 10 years |
| Air flow filters | Every year | Every 10 years |
| Air Flow regulation mechanism | Every year | Every 10 years |
| Canopy spring | Every year | When necessary |
| Tube starters(if applicable) | With every tube change | With every tube change |
| Tubes | Every 600-800 hours | Every 600-800 hours |
| Facial tanners | Every 600-800 hours | Every 600-800 hours |
| Facial glass filters | Every year | Every year |
| Acrylic panel – Bench | Every year | When necessary |
| Acrylic panel – Canopy | Every year | When necessary |
| Mechanical parts | Every year | Every 5 years |
| Temperature sensor | Every year | Every 5 years |
| Control Panel | Every year | When necessary |
| Pressure sensors | Every year | Every 10 years |
| Chip Card(if applicable) | When necessary | When necessary |
| High pressure tubes(if applicable) | When necessary | When necessary |
| Outer acrylic parts | Every Year | When necessary |
| Decorative elements | Every Year | When necessary |
| Deep Clean | Every Year | Every year |